NBS Product Manual and NBG Certified Erection Details
Product definition, as shown in the NBS Product Manual below, is in process of transitioning to Nucor Buildings Group (NBG) Certified Erection Details. Slight changes may have occurred on pages marked “LEGACY PRODUCT INFORMATION”. Current information can be found within the NBG Certified Erection Details on the lower portion of this page. Please contact your local division for verification of the detail’s status. Throughout the sections, you will notice blue hyperlinks that will take you to another part of the manual or open a .dwg file.
Google Chrome is recommended when opening .dwg files
1.0 – Introduction
2.0 – Standard Product Summary
3.0 – Specification Guide
4.1 – Primary Framing
4.2 – Endwall Framing
4.3 – Secondary Framing
4.4 – Bracing Systems
4.5 – Mezzanine System
4.6 – Crane Systems – See NBG Certified Details
4.7 – Existing Building Tie-In Systems
4.8 – Future Expansion Details
4.9 – Tilt-Up / Pre-Cast Wall
4.10 – Non-Load Bearing Masonry Wall
4.11 – Structural Parapet Details
4.12 – Auxiliary Rafter Details
4.13 – Lean-To Rafter Details
4.14 – Spandrel Beam Details
5.0 – Nucor CFR Standing Seam Roof System
5.5 – Nucor VR16 II Vertical Rib Standing Seam Roof
6.0 – Classic Wall & Roof Sheeting
6.5 – SR2 Insulated Standing Seam Roof Panel
6.6 – HR3 Insulated Roof Panel
6.7 – Insulated Wall Panel
7.1 – Standard Trim
7.2 – Canopies & Eave/Rake Extensions
7.3 – Standard Fascia
7.4 – Partitions & Draft Curtains
7.5 – Standard Liner Panel
7.6 – Non-Structural Parapet
7.7 – Inset/Outset Condition
7.8 – Horizontal Gutter (Steep Slope)
8.0 – Accessories
9.0 – Foundation Reactions
10.0 – Anchor Bolt Details
11.1 – Frame Details – See NBG Certified Details
11.2 – Purlin/Girt Details
11.3 – Bracing Details
11.4 – Nucor Classic Roof Details
11.5 – Wall Sheeting Details
11.6 – Nucor CFR Details
11.7 – Nucor VR16 II Details
11.8 – Insulated Roof Panel Details
11.9 – Insulated Wall Panel Details
12.0 – Glossary of Terms
Please reference the NBG Certified Erection Details for projects designed using the new common details. For legacy technical information on projects not affected by the new common details, continue to reference the NBS Product Manual above. If you need further assistance, please reach out to your Sales Representative or Project Coordinator.
Primary Framing
A0 – General
AB – Post & Beam Endwalls
AD – Exp EW Column to RF Rafter
AF – Rod Cable SW Wind Bracing
AG – Flange Bracing
AH – Crane Systems
AJ – Portal Frame
AK – Brace Strut
AN – Eave Extensions
AP – Mezzanines
IAA – Flange Brace w/Liner
Roof Secondary
BA – Low Eave
BB – Interior Details
BC – High Eave
BD – Rake Detail
BE – Purlin Bracing
BF – General Joist & Deck Notes
BG – Shortspan (K-Series) Joist
BH – Longspan (LH-Series) Joist
BI – Joist Bridging
BK – Roof Framed Openings
BM – Nested Purlins
Wall Secondary
C0 – General
CA – SW EW Flush Girt Conditions
CB – SW EW Insert Girt Conditions
CC – SW EW Bypass Girt Conditions
CD – Flush Corner Girt Conditions
CE – Inset Corner Girt Conditions
CF – Bypass Corner Girt Conditions
CG – Framed Opening Conditions
CJ – Inside Corner Girt Connections
CM – Nested Girt Details
CP – Girt Bracing
R-Boost Elevated Insulation
FA – General Details
FB – Low Eave Simple Trim
FC – Low Eave Sculptured Trim
FD – Low Eave Gutter
FE – Rake Details
FF – High/Low Conditions
FG – Ridge
FH – High Eave
FI – High Eave Parapet
FK – Parapet Gutter
FL – Valley Gutter
FN – Roof Curb
FO – Rake Ext/Eave Canopies
Trapezoidal Roof Panels
EM6 – Translucent Panels
EN6 – Roof Curbs
Composite Trapezoidal Roof
Vertical Rib Panels
Insulated Roof Panels
EN4 – HR3 Roof Curbs
EN5 – SR2 Roof Curbs