| Fiberglass Insulation |
|
Nucor recommends that the fiberglass insulation be installed in two layers, as shown above. |
| Layered Insulation |
|
This recommended layer method of insulation helps ensure that there are no gaps in the insulation. (Gaps in the insulation can cause condensation problems.) |
| Insulation |
| |
Insulation is not by Nucor |
| Roof Deck |
|
Roof deck is fabricated in accordance with SDI specifications and tolerances. Nucor does not offer warranties on liner decking. |
| Panel Clips Fasteners |
|
Panel clips fasteners must engage the Z-Bar member. Self-drilling fasteners without a washer are utilized. |
| Z-Bar Fasteners |
|
The Z-Bar fasteners must engage the deck. Self-drilling fasteners without a washer are utilized. |
| Vapor Barrier |
|
Vapor barrier is required in all
composite “CFR”™ applications to help
avoid condensation.
Vapor barrier is not provided by Nucor Building Systems. |
|
|
| UL90 Requirements |
|
For UL90 Requirements, please contact Nucor. |
|
|
| Z-Bar Spacing |
|
Z-bars (16 gauge minimum) are spaced either 4'-0" or 5'0" apart to accommodate standard fiberglass insulation roll widths. |
|
|
|
Nucor "Composite CFR"™
Rigid Board Insulation with Z-Bars Detail
(Scroll down for Rigid Board Insulation Detail) |
 |
|
|
|
|
|
|
| Rigid Board Insulation |
|
NBS recommends that the rigid board insulation be installed in two layers, with the top layer being 1" thick, as shown above |
| Layered Insulation |
|
This recommended layered method of insulation helps ensure that there are no gaps in the insulation. Gaps in the insulation can cause condensation problems. |
| Insulation |
|
Insulation is not by Nucor |
| Roof Decking |
|
Roof deck is fabricated in accordance with SDI specifications and tolerances. Nucor does not offer warranties on liner decking. |
| Panel Clips Fasteners |
|
Panel clips fasteners must engage the Z-Bar member. Self-drilling fasteners without a washer are utilized. |
| Z-Bar Fasteners |
|
Z-Bar fasteners must engage the deck. Self-drilling fasteners without a washer are utilized. |
|
| Vapor Barrier |
|
A Vapor barrier is required in all Composite CFR applications to avoid condensation. Vapor barrier is not provided by Nucor. |
| UL90 Requirements |
|
For UL90 requirements, please contact Nucor. |
| Z-Bar Spacing |
|
Z-Bars (16 gauge minimum) are spaced 4'-0" apart to accommodate standard rigid board insulation widths. |
|
|
|
Nucor "Composite CFR"™
Rigid Board Insulation Detail
|
|
 |
| Rigid Board Insulation |
|
NBS recommends that the rigid board insulation be installed in two layers, with the top layer being 1" thick, as shown above. |
| Layered Insulation |
|
This recommended layered method of insulation helps ensure that there are no gaps in the insulation. Gaps in the insulation can cause condensation problems. |
| Insulation |
|
Insulation is not by Nucor |
| Roof Decking |
|
Roof deck is fabricated in accordance with SDI specifications and tolerances. Nucor does not offer warranties on liner decking. |
| Panel Clips Fasteners |
|
Panel clips fasteners must engage the roof secondary member. Self-drilling fasteners without a washer are utilized. Nucor recommends that the deck and roof secondary member be pre-drilled for the panel clip fasteners to help avoid fastener drill point breakage. |
|
| Vapor Barrier |
|
A Vapor barrier is required in all Composite CFR applications to avoid condensation. Vapor barrier is not provided by Nucor. |
| UL90 Requirements |
|
For UL90 requirements, please contact Nucor. |
|